Our Products

Multi Parameter Patient Monitor Touch screen

Company Name: TRISMED

Origin: Korea

Trade Mark: TRISMED

Model: vitapia 7200T

Specifications:

-Semi-Modular and integrated design
• Multi-parameter: ECG, NIBP, Sp02, Resp, Temp
• Optional parameter: 12-ch ECG, 2-IBP, 4-IBP, EtC02, Anesthetic gas
• Easy Operation with touch and button navigation
• Low power consumption : 6 hour battery operation
• Short System booting time
• Low perfusion and accurate measurement (Sp02)
• High qualified connector for long lasting use and reliable measurement
• Internal large memory for over 60 days data saving
• HDMI video output
• External micro SD card slot
• Optional central network system (wire/wireless)
■ Display :
• Device:
15" (Type 7012S,7000K), Color TFT LCD , Touch Sccreen
• Messages:
8 Waveforms Maximum
1 Alarm LED (yellow/Red)
1 Power LED (Green)
1 Battery Charge LED (Green)
3 Sound mode corresponding Alarm mode
ECG :
• Lead Mode : 5 Leads(R, L, F, N, C or RA, LA, LL, RL, V)
• Lead Selection: I, II, III, avR, avL, avF, V
• Waveform: 2ch
• Lead Mode: 3 Leads(R, L, F)
• Gain: x2.5mm/mV, 5.0mm/mV, x10mm/mV, x20mm/mV auto
• HR and Alarm Range:
Adult 15~300bpm
Neo/Ped 15~350bpm
• Differential Input Impedence: ˃ 5 MΩ
• CMRR:
Monitor ˃ 105dB
Operation ˃ 105dB
Diagnosis ˃ 85dB
• Electrode offset potential: ±300 mV
• Leakage Current: ˂ 10µA
• Baseline Recovery: ˂ 3s After Defi.
• ECG Signal Range: ±8mV(Vp-p)
• Bandwidth:
Surgery 1~15 Hz
Monitor 0.5~35Hz
Diagnostic 0.05~100Hz
• ST Segment Monitoring Range:
Measure and Alarm -2.0~+2.0mV
• Calibration Signal: 1mV(Vp-p), ±5% Accuracy
• ARR Detecting :
Type : ASYSOLE, VFIBNTAC, COUPLET, BIGMINY, TRGEMINY,
R, ON T, VT˃2, PVC, TACHY, BRADY, MISSED BEATD,
PNP, PNC
• Alarm : Available
Review : Available .
■ Recall :
• Trend Recall:
Short : 1hrs, 1 Second Resolution
Long : 72 hrs, 1Min. Resolution
• Alarm Event Recall: 60 alarm events of all parameters and 8/16/32 seconds of corresponding waveform
• NIBP Measurement Recall: 400 NIBP measurement data
■ RESPIRATION :
• Method:Impedance between R-F(RA-LL)
• Differential Input Impedance: ˃2.5MΩ
• Measuring and alarm Range: 0.3 ~ 2.5 Hz
Adult 0~120 rpm Neo/Ped 0~150 rpm
• Resolution: 1 rpm
• Accuracy: ± 2 rpm
Apnea Alarm : 10 ~ 40 S
■ NIBP :
• Method: Oscillometric
• Mode: Manual, Auto, STAT
• Measuring Interval in AUTO Mode:
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 Min.
• Measuring Period in SATA Mode: 5 Min.
• Pulse Rate Range: 40~240 bpm
• Alarm type: SYS, DIA, MEAN
• Measuring and alarm Range:
Adult Mode 10~270 mmHg
Pediatric Mode 10~200 mmHg
Neonatal Mode 10~135 mmHg
• Resolution: Pressure 1 mmHg
• Accuracy: Pressure
Maximum Mean error ± 5 mmHg .
Maximum Standard deviation ± 8 mmHg .
RESPIRATION :
• Method:Impedance between R-F(RA-LL)
• Differential Input Impedance: ˃2.5MΩ
• Measuring and alarm Range: 0.3 ~ 2.5 Hz
Adult 0~120 rpm
Neo/Ped 0~150 rpm
■ SpO2 :
• Measuring Range: 0~100%
• Alarm Range: 0~100%
• Resolution: 1%
• Accuracy: 70%~100% ± 2%
0%~69% unspecified
• Actualization interval: About 1 Sec.
• Alarm Delay: 10 Sec.
• Pulse Rate Measuring and Alarm Range: 30~250bpm
• Resolution: 1bpm
• Accuracy: ± 2bpm
TEMPERATURE :
• Channel: 2-ch(7012S, 7010S, 7000K(option))/1-ch(7010E,7000K)
• Measuring and Alarm Range: 0~50°C
• Resolution: 0.1°C
• Accuracy: ±0.1°C
• Actualization interval: About 1
• Average Time Constant ˂ 10
Signal Interface :
• External Display :Standard VAG
• ECG Output: BNC
• Amplitude: 1V/mV
• Accuracy:˂ 5%
• Impedance: 50 Ω
• Signal Delay: ˂ 20 Ms
Power Supply: 100/240VAC, 50/60Hz, Pmax = 80 VA
Battery : Rechargeable 2.3 A/Hr 12V Lead-Acid battery

Optional :
-CO2

-IBP

• Accessories :
1- ECG Cable
2- SPO2 Probe
3- Tempreture Probe
4- NIBP