Company Name: TOP
Origin: japan
Trade Mark: TOP
Model: MJ-210
Specifications:
• Technical specification :
Product Name TOP INFUSION PUMP MJ-210
Power Supply AC adapter: Input AC100 240V+10%, 50/60Hz :Output DC5V/2A Internal Battery: Rechargeable DC3.7V 2500mAh Li-ion battery Battery life: Approx. 4hours
Input Current AC power supply: 0.9A
Applicable
Infusion Set [Recommendation] TOP SOLUTION INFUSION SET U series
[Available] INFUSION SET other thon U series
Flow Rate Range Useries mode 0.1 99.9mL/h (0.1 mL/h increments)
100 1200mL/h (1 mL/h increments)
General mode 15drops/mL Infusion set: 1-400mL/h (1 mL/h increments) 20drops/mL Infusion set: 1 360mL/h (1 mL/h increments) 60drops/mL Infusion set: 1 150mL/h (1 mL/h increments)
Volume Limit Range 0.I 9999.9mL (0.1 mL increments)
Total Volume Range 0.0 9999.9mL (0.1 mL increments)
Infusion Accuracy* Useries mode +5% (IEC60601-2-24, Clinical situations)
General mode +10% (IEC60601-2-24, Clinical situations, Water or Saline)
Occlusion Detection
Pressure* Downstream occlusion Upstream occlusion
Useries mode General mode
Oc.Lv.3
oc.Lv.2 Oc.Lv.1 Oc.Lv.0 High 120+30kPa Medium 90+30kPa
Low 60+30kPa Lowest 30+20kPa High Medium Low Lowest
0--100kPo
Air-in-line Detection Sensitivity* Ar.Lv.0 Ar.Lv.1 Ar.Lv.2 High (Approx. 50uL)
Medium (Approx. 0.1mL/15minutes) Low (Approx. 1 mL/15minutes)
Alarm
and Information Volume limit” / Upstream occlusion* / Downstream occlusion* / Air-in-line” /
Empty container* / Flow error / Free flow / DROP SENSOR / Clamp / Auto power OFF / Power loss / System error* / Volume limit pre- / No battery / Low battery / No action / Data reset / Unspecified flow rate / Set value confirmation / Maintenance timer / Power supply switch
Special Functions Automatic INFU3ION SET attaching function / Automatic clamp confirmation function/ Anti-bolus function / KVO function / 3tandby function / Auto power OFF function / Repeat alarm / Buzzer setting / Power supply swithch notice / Key-lock function / Maintenance timer / History function / Alarm setting confirmation function
Environmental Conditions Ambient temperature: 10 40°C
Relative humidity: 20 - 90% (Noncondernsing)
Atmospheric pressure: 70 l06kPa
Service Life 6 years (based on self certification using TOP corporation data)
(Assuming inspection and maintenance are carried out as indicated and consumable parts are replaced as needed.j
Classification ClOSs II / Internally Powered Equipment / Type CF / IPX2 / Continuous operation
Dimensions W180 x H113 x L202 mm
Weight Approx. 1.8kg (Including Clamp and Battery)
Our professional experts will help you.