stand operation halogen light

Company Name: HEALTH

Origin: china

Trade Mark: HEALTH

Model: DL500

Download stand operation halogen light

Specifications:

Specifications DL500
DL500 Battery operated decorative lamps
having CE ISO
2600 mirrors reflector
60,000lux
DL500 Battery operated decorative lamps
Operating light, each reflector use 3800 multimirrors. Also has backup bulb system, if one break, another bulb will light in 0.3s.
Technical parameters
Lamp head DL500
Illumination 60000 lx or more
Diameter of light spot 120-300 mm
Depth of illumination 700 mm
Color temperature 4250 k
Increase of temperature 10 or less
Power 150 W
Radius for move of lamp holder 1800 mm
Damage of main lamp Switch automatically with 0.3 second
Multi-mirror 26000 pieces

stand operation halogen light

Specifications DL500
DL500 Battery operated decorative lamps
having CE ISO
2600 mirrors reflector
60,000lux
DL500 Battery operated decorative lamps
Operating light, each reflector use 3800 ... read more

Patient Monitor

Company Name: Hwatime

Origin: china

Trade Mark: Hwatime

Model: H9

Download Patient Monitor

Specifications:

• Technical specification :
>15" Colur TFT Display, led backlight .
> Operating Mode Selection: Neonatal/Pediatric/Adult.
> Visual and Audio alarms, adjustable.
> Patient management, name and age and id.
> Network with Central Station Software,
> Built-in removable and rechargeable lithium battery,
> easy operating UI with both Keypad menu.
> Powerful data storage and managment, Trend graph,Trend table, etc
>Arrythmia analysis and S-T segment analysis.
> Compatible to Neonatal, Pediatric, Adult Patients
Standard parameters:
3/5-Lead ECG, Hwatime SpO2 ,NIBP, RESP, 2-Temp, PR
Optional:
EtCO2 , Touchscreen , Thermal Recorder ,WLAN accessory ,
Nellcor-SPO2 ,2-IBP Masimo SpO2,Masimo AGM.

Patient Monitor

• Technical specification :
>15" Colur TFT Display, led backlight .
> Operating Mode Selection: Neonatal/Pediatric/Adult.
> Visual and Audio alarms, adjustable.
> Patient management, name and ag ... read more

Syringe pump TOP-5300

Company Name: TOP

Origin: japan

Trade Mark: TOP

Model: TOP-5300

Download Syringe pump TOP-5300

Specifications:

Technical Specification:
1) power SUPPLY:
• AC power source : AC 100 to 240 V ±10% 50/60Hz(approx. )
• ExtrenalDC power source : DC 12.7 to 15V (exact )
• Built-in battery : Rechargeable, DC 12V 700mAh NI-CD Model : BP-53
• Continous operation : Approx. two hours ( when a new battery is fully Recharged with 5mL/h set)
2) power consumption external :
• AC power source : 0.3A ( approx.)
• External DC power source : 0.5A ( exact )
3) Applicable syringes
10mL, 20mL, 30mL and 50mL syrings from
1) TOP, TERUMO, B-D or B. BRAUN
2) B-D, TERUMO, MONOJECT or B.BRAUN can be used ( in the auto selecation [*] mode, only the 50 mL syringe can be used ).
4) flow rang
• 0.1-400.0 mL/h (10mL syringe)
• 0.1-700.0 mL/h (20mL syringe)
• 0.1-900.0 mL/h (30mL syringe)
• 0.1-1500.0mL/h (50mL syringe )
• ( setting Adjustable in 0.1mL increments.)
5) total infusion volume range
• 0.1-999.9 mL
6) infusion accuracy
Brand – specififed mode
• Mechanical accuracy : ±1%
• Accuracy including the syring : ±3%
Auto selection [*] mode(only 50ml syringe can be used.)
• Mechanical accuracy : ±1%
• Accuracy including the syringe :±3%
҉ Accuracy obtained when infusion is performed for over one hour
at an infusion rate of 1.0mL/h or more.
7)Bolus rate
• Approx 400.0mL/h (10mL syringe)
• Approx 700.0mL/h (20mL syringe)
• Approx 900.0mL/h (30mL syringe)
• Approx 1500.0mL/h (50mL syringe)
4- step selection
• Extra high : 119.7±40.0kpa/ 900±300mmHg/ 1.22±0.41 kgf/ cm2
• High : 93.1±33.3kpa/ 700±250mmHg/ 0.95±0.34 kgf/ cm2
• Middle: 66.5±26.7kpa/ 500±200mmHg/ 0.68±0.27Kgf/cm2
• Low : 39.9±20.0Kpa/ 300±150mmHg/ 0.41±0.20Kgf/ cm2
9)Alarm
Low volume (inactive in the auto selection [*] mode), occlusion, lowbattery, syringebarel/ syring plunger clamp disengaged, power source switch, remainder, CPU error.
10) Special functions
• Operation Reminder:If the system is left in the suspend state for approximately three minutes, a buzzer will sound.
• Auto power off: If the system is left in the "Operation Reminder" state for another three minutes while ti is powerd by an internal battery, it will be automatically shut off .
• Alarm Repeat: If two minutes have elapsed without resetting the alarm after it is silenced the alarm sounds again.
• Data memorize : Infusion rate set value/Total infusion volume storage setting is allowed.
• Buzzer setting : Presence/Absence of wait tone and operation tone can be speficied.
• Power source switch alarm : Notifies by the alarm sound that power is no longersupplied from the AC or DC power source and the system has entered the battery operation mode.
11) operation conditions :
• Ambient temperture : 10 to 40 °C
• Relative humidity : 30 to 85% ( no condensation )
• Atmospheric pressure : 70 to106kpa
12) Transportation and storage conditions :
• Ambient temperture : -10 to 45 °C
• Relative humidity : 10 to 90% ( no condensation )
• Atmospheric pressure : 50 to 106kpa
13) classification :
• Class I and Internally powerd equipment, Type CF♥, IPX1 (drip proof)
14) fuse : T1A
15)External dimensiobs / weight :
• Approx 320(W)x116(H) X 139(D)mm / approx 2.2kg

Syringe pump TOP-5300

Technical Specification:
1) power SUPPLY:
• AC power source : AC 100 to 240 V ±10% 50/60Hz(approx. )
• ExtrenalDC power source : DC 12.7 to 15V (exact )
• Built-in battery : Rechargeable, ... read more

Infusion Pump MJ-210

Company Name: TOP

Origin: japan

Trade Mark: TOP

Model: MJ-210

Download Infusion Pump MJ-210

Specifications:

• Technical specification :

Product Name TOP INFUSION PUMP MJ-210

Power Supply AC adapter: Input AC100 240V+10%, 50/60Hz :Output DC5V/2A Internal Battery: Rechargeable DC3.7V 2500mAh Li-ion battery Battery life: Approx. 4hours
Input Current AC power supply: 0.9A
Applicable
Infusion Set [Recommendation] TOP SOLUTION INFUSION SET U series
[Available] INFUSION SET other thon U series


Flow Rate Range Useries mode 0.1 99.9mL/h (0.1 mL/h increments)
100 1200mL/h (1 mL/h increments)

General mode 15drops/mL Infusion set: 1-400mL/h (1 mL/h increments) 20drops/mL Infusion set: 1 360mL/h (1 mL/h increments) 60drops/mL Infusion set: 1 150mL/h (1 mL/h increments)
Volume Limit Range 0.I 9999.9mL (0.1 mL increments)
Total Volume Range 0.0 9999.9mL (0.1 mL increments)

Infusion Accuracy* Useries mode +5% (IEC60601-2-24, Clinical situations)
General mode +10% (IEC60601-2-24, Clinical situations, Water or Saline)



Occlusion Detection
Pressure* Downstream occlusion Upstream occlusion
Useries mode General mode
Oc.Lv.3
oc.Lv.2 Oc.Lv.1 Oc.Lv.0 High 120+30kPa Medium 90+30kPa
Low 60+30kPa Lowest 30+20kPa High Medium Low Lowest

0--100kPo


Air-in-line Detection Sensitivity* Ar.Lv.0 Ar.Lv.1 Ar.Lv.2 High (Approx. 50uL)
Medium (Approx. 0.1mL/15minutes) Low (Approx. 1 mL/15minutes)


Alarm
and Information Volume limit” / Upstream occlusion* / Downstream occlusion* / Air-in-line” /
Empty container* / Flow error / Free flow / DROP SENSOR / Clamp / Auto power OFF / Power loss / System error* / Volume limit pre- / No battery / Low battery / No action / Data reset / Unspecified flow rate / Set value confirmation / Maintenance timer / Power supply switch


Special Functions Automatic INFU3ION SET attaching function / Automatic clamp confirmation function/ Anti-bolus function / KVO function / 3tandby function / Auto power OFF function / Repeat alarm / Buzzer setting / Power supply swithch notice / Key-lock function / Maintenance timer / History function / Alarm setting confirmation function
Environmental Conditions Ambient temperature: 10 40°C
Relative humidity: 20 - 90% (Noncondernsing)
Atmospheric pressure: 70 l06kPa

Service Life 6 years (based on self certification using TOP corporation data)
(Assuming inspection and maintenance are carried out as indicated and consumable parts are replaced as needed.j
Classification ClOSs II / Internally Powered Equipment / Type CF / IPX2 / Continuous operation
Dimensions W180 x H113 x L202 mm
Weight Approx. 1.8kg (Including Clamp and Battery)

Infusion Pump MJ-210

• Technical specification :

Product Name TOP INFUSION PUMP MJ-210

Power Supply AC adapter: Input AC100 240V+10%, 50/60Hz :Output DC5V/2A Internal Battery: Rechargeable DC3.7V 2500mAh Li-ion ba ... read more

Syringe pump TOP-5530

Company Name: TOP

Origin: japan

Trade Mark: TOP

Model: TOP-5530

Download Syringe pump TOP-5530

Specifications:

Technical Specification:
1) power SUPPLY:
• AC power source : AC 100 -127 ±10% 50/60Hz (for 100V Area) , Ac 200-240 V ±10% 50/60Hz (for 100V Area)
• DC power supply : DC 12V ±5% (type: ST55-4)
• internal battery : DC3.6V 1500mAh NI-MH (type : BP-55)
battery life is approximately 12 hours (at flow rate of 5 mL/h using new battery in fully recharged state )
• Built-in battery : Rechargeable, DC 12V 700mAh NI-CD Model : BP-53
• Alkaline battery : usesfour LR6 type , AA size alkaline batteries DC6V battery life is approximately24 hours (at flow rate

2) power consumption external :
• AC power source : 0.3A ( approx.)
• External DC power source : 0.5A ( exact )
3) Applicable syringes
10mL, 20mL, 30mL and 50mL syrings from
1) TOP, TERUMO, B-D or B. BRAUN
2) B-D, TERUMO, MONOJECT or B.BRAUN can be used ( in the auto selecation [*] mode, only the 50 mL syringe can be used ).
4) flow rang
• 0.1-400.0 mL/h (10mL syringe)
• 0.1-700.0 mL/h (20mL syringe)
• 0.1-900.0 mL/h (30mL syringe)
• 0.1-1500.0mL/h (50mL syringe )
• ( setting Adjustable in 0.1mL increments.)
5) total infusion volume range
• 0.1-999.9 mL
6) infusion accuracy
Brand – specififed mode
• Mechanical accuracy : ±1%
• Accuracy including the syring : ±3%
Auto selection [*] mode (only 50ml syringe can be used.)
• Mechanical accuracy : ±1%
• Accuracy including the syringe :±3%
҉ Accuracy obtained when infusion is performed for over one hour
at an infusion rate of 1.0mL/h or more.
7)Bolus rate
• Approx 400.0mL/h (10mL syringe)
• Approx 700.0mL/h (20mL syringe)
• Approx 900.0mL/h (30mL syringe)
Approx 1500.0mL/h (50mL syringe)

4- step selection
• Extra high : 119.7±40.0kpa/ 900±300mmHg/ 1.22±0.41 kgf/ cm2
• High : 93.1±33.3kpa/ 700±250mmHg/ 0.95±0.34 kgf/ cm2
• Middle : 66.5±26.7kpa/ 500±200mmHg/ 0.68±0.27Kgf/cm2
• Low : 39.9±20.0Kpa/ 300±150mmHg/ 0.41±0.20Kgf/ cm2
9)Alarm
Low volume (inactive in the auto selection [*] mode), occlusion, low battery, syringe barel/ syring plunger clamp disengaged, power source switch, remainder, CPU error.
10) Special functions
• Operation Reminder: If the system is left in the suspend state for approximately three minutes, a buzzer will sound.
• Auto power off: If the system is left in the "Operation Reminder" state for another three minutes while ti is powerd by an internal battery, it will be automatically shut off .
• Alarm Repeat: If two minutes have elapsed without resetting the alarm after it is silenced the alarm sounds again.
• Data memorize : Infusion rate set value/Total infusion volume storage setting is allowed.
• Buzzer setting : Presence/Absence of wait tone and operation tone can be speficied.
• Power source switch alarm : Notifies by the alarm sound that power is no longer supplied from the AC or DC power source and the system has entered the battery operation mode.
11) operation conditions :
• Ambient temperture : 10 to 40 °C
• Relative humidity : 30 to 85% ( no condensation )
• Atmospheric pressure : 70 to106kpa
12) Transportation and storage conditions :
• Ambient temperture : -10 to 45 °C
• Relative humidity : 10 to 90% ( no condensation )
• Atmospheric pressure : 50 to 106kpa
13) classification :
• Class I and Internally powerd equipment, Type CF♥, IPX1 (drip proof)
14) fuse : T1A
15)External dimensiobs / weight :
• Approx 320(W)x116(H) X 139(D)mm / approx 2.2kg

Syringe pump TOP-5530

Technical Specification:
1) power SUPPLY:
• AC power source : AC 100 -127 ±10% 50/60Hz (for 100V Area) , Ac 200-240 V ±10% 50/60Hz (for 100V Area)
• DC power supply : DC 12V ±5% (type: ST55 ... read more

infusion pump TOP-2300

Company Name: TOP

Origin: japan

Trade Mark: TOP

Model: TOP-2300

Download infusion pump TOP-2300

Specifications:

Technical Specification:
1) pump type
• Peristaltic finger
2) Applicable IV sets
• TOP IV sets H- Series ( TOP- H ) for infusion Pumps, and other standard IV sets (,20or 60 drops/mL)
3) Flow rate
• 1.0-600mL/h(TOP-H series dedicated IV set)
• 3-300 mL/h (standard 20 drops/mL IV set)
• 1.0-150 mL/h (standard 60 drops/mL IV set)
4)volume limit range
• 1 to 9,999 mL in 1 mL increments
5)Total volume range:
• 0 to 9,999 mL in 1 mL increments
6)Purge flow rate :
• Maximum flow rate of iv set used
7)KVO flow rate :
• 1-10ml/h ( 1ml/h increments )
8) infusion accuracy
• ±7% when TOP- H sets are used
• ±10% when other common IV sets are used
9) Alarms
• Empty container, Occlusion Door open Air-in-line, Low battery, Infusion complete, Power source switched, Operator error, and other deviced malfunctions
10)Air bubble detection
• Can be set to any or 3 levels, 50µL 0.1mL/15min, 1mL/15min
11)Occlusion detection pressure
Can be set to any of 4 levels when TOP - H sets are used :
• P1-3: ≤ 150.0 kpa ( ≤ 1,100mmHg)
• P1-2: ≤ 120.0 kpa ( ≤ 900mmHg)
• P1-1: ≤ 80.0 kpa ( ≤ 600mmHg)
• P1-0: ≤ 40.0 kpa ( ≤ 300mmHg)
Can be used to either of 2 levels when other common IV sets are used :
• P2-1: ≤ 150.0 kpa ( ≤ 1,100mmHg)
• P2-0: ≤ 80.0 kpa ( ≤ 600mmHg)
12)Special functions
• Automatic Shutoff: When the infusion pump is operating on battery power and has been left for 3 minutes with the infusion stopped or in an alarm state, the buzzer sounds. After the buzzer has been left sounding for 3 minutes, the power turns off automatically to conserve the battery.
• Alarm repeat: Unless the cause of an alarm is corrected within 2 minutes after the operator has pressed the "silence" buzzer key, the buzzer will sound again to remind the opertor of the problem.
• Data memorize function: Retains the most recent flopw rate, volume limit or total volume infused for the next used.
• Sound setting: Audible indication of standby and infusion in progress can be turned on or off.
• Power Source Switch alarm: An alarm sounds when AC power supply has stopped and the unit has switched over to battery operation.
13)Operating conditions
• Ambient temperature: +5 to 40°C
• Humidity: 20 to 90% (no condensation)
• Pressure: 70 to 106 kPa
14)Storage conditions
• Ambient temperature: -10 to 45°C
• Humidity: 20 to 90% (no condensation)
• Pressure: 70 to 106 kPa
15)power source
• AC 100-240V ±10%, 50/60Hz
• Internal battery: Rechargeable DC 12 V, 1800 mAh,
Ni-MH (type BP- 23).
• Battery life is approx. 4 hour when using a new, fully charged battery at a fluid delivery rate of 25 mL/h.
• External DC power supply: DC 15 V
16)Input current
• AC power supply: 0.3 A~ external DC power supply: 1.5A
17) Classification
• Class II, type CF, IPX1 (drip- proof)
18) Dimensions:84(W) x 190 (H) x 185 (D) mm
19)Weight :pprox. 2.0 kg

infusion pump TOP-2300

Technical Specification:
1) pump type
• Peristaltic finger
2) Applicable IV sets
• TOP IV sets H- Series ( TOP- H ) for infusion Pumps, and other standard IV sets (,20or 60 drops/mL)
3) F ... read more

Let Us Help You to Find a Solution That Meets Your Needs